认证 |
|
All Winmate's RUGGMATE Marine Grade products are
designed and carried out applicable tests according to : |
IEC60945 (Fourth Edition, Aug 2002)
Maritime Navigation and Radio-communication
Equipment and Systems
DNV Standard for Certification 2.4 (April 2006)
Environmental Test Specification for Instrumentation
and Automation Equipment
IACS-E10 (2006)
Concerning Electronic Installations
CE/ FCC Class B |
 |
|
|
|
|
 |
DET NORSKE VERITAS (DNV), one of the leading the ship classification societies, is an autonomous and independent foundation for safeguarding life, property and the environment in maritime environment including sea and onshore.
Getting DNV type approval making sure the products meet a set of requirement through design, manufacture, and operation. DNV undertakes the marine certification to make
verification for the productto fit in different kind of maritime applications.
For more detail information about DNV services, found on DNV website at
www.dnv.com/maritime |
|
|
认证等级 |
|
认证标准
DNV classifies tests in four levels base on the product applied location in ships-A, B, C, and D.
For worseharsh environment use, the much strict standard testing is required. (See Table of Location
Classes Selection Guide) Standards for Certification including contain principles, acceptance criteria and
practical information related to the Society's consideration of objects, personnel, organizations,
services and operations. A list of Standards for Certification is found in the latest edition of Pt.0 Ch.1
of the ”Rules for Classification of Ships” and the ”Rules for Classification of High Speed, Light Craft
and Naval Surface Craft” |
|
Table of Location Classes Selection guide |
Column I |
Column II |
Parameters |
Location within main area |
MAIN AREAS ON BOARD |
Machinery
spaces |
Control room,
Accommodation |
Bridge |
Pump room, Holds,
Rooms with no heating |
Open Deck |
Temperature |
Inside cubicles, desks, etc. with
temperature rise of 5°C or more |
B |
B |
B |
D |
D |
All other locations |
A |
A |
A |
C |
D |
Humidity |
Locations where special precautions
are taken to avoid condensation |
A |
A |
A |
A |
A |
All other locations |
B |
B |
B |
B |
B |
Vibration |
On machinery such as internal combustion engines, compressors,
pumps, including piping on such
machinery |
B |
— |
— |
B |
B |
Masts |
— |
— |
— |
— |
C |
All other locations |
A |
A |
A |
A |
A |
EMC Electromagnetic
compatibility |
All locations within specified main
Areas |
A |
A |
B |
A |
B |
Enclosure |
Submerged application |
D |
— |
— |
D |
D |
Below floor plates in engine room |
C |
— |
— |
— |
— |
All other locations |
B |
A |
A |
B |
C |
|
|